VICTRON ENERGY BatteryProtect 12/24V 65A Protector

Бестселлер
108375216
5 515 ₽

Мы собрали лучшие предложения по оригинальным брендовым товарам из зарубежных магазинов, выстроили надежную систему доставки и не тратим средства на аренду торговых помещений - это позволяет сделать цены для вас намного ниже местных магазинов. 

Непривычно покупать качественные вещи дёшево? Пора начинать это делать вместе с LiteMF Market!»

  • Бренд Victron Energy
  • Доставка из Испании
  • LiteMF Delivery
  • Стоимость доставки заказа в Россию от 399 ₽

Характеристики

Прочие свойства

EAN
0000000NT-795
Бренд
Victron Energy

Свойства

Цвет
Синий

Описание

Features: - The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. - 12/24V auto ranging: The BatteryProtect automatically detects system voltage - Programming made easy: The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen. A special setting for Li-ion batteries: In this mode the Battery Protect can be controlled by the VE.Bus BMS. - Ultra low current consumption: This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li -ion battery datasheet and the VE.Bus BMS manual for more information. - Over voltage protection: To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V. - Ignition proof: No relays but MOSFET switches, and therefore no sparks. Delayed alarm output: The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. - Delayed load disconnect and delayed reconnect: The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been startedfor example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage. Specifications: - Maximum continuous load current: 65A - Peak current (during 30 seconds): 250A - Operating voltage range: 635V - Current consumption: - When on: 1,5 mA - When off or low voltage shutdown : 0,6 mA - Alarm output delay: 12seconds - Maximum load on alarm output: 50 mA (short circuit proof) - Load disconnect delay: 90 seconds - Load reconnect delay: 30 seconds - Default threshold: Disengage: 10,5V or 21V Engage: 12V or 24V - Operating temperature range: Full load: -40°C to +40°C (up to 60% of nominal load at 50°C) - Connection: M6 - Weight: 0,2kg0.5 lbs - Dimensions (hxwxd): 40 x 48 x 106mm 1.6 x 1.9 x 4.2 inc