REHAB MEDIC Digital RM EV805 EMS Electrostimulator

Бестселлер
109165995
9 463 ₽

Мы собрали лучшие предложения по оригинальным брендовым товарам из зарубежных магазинов, выстроили надежную систему доставки и не тратим средства на аренду торговых помещений - это позволяет сделать цены для вас намного ниже местных магазинов. 

Непривычно покупать качественные вещи дёшево? Пора начинать это делать вместе с LiteMF Market!»

Характеристики

Дизайн

Цвет
Черный, Серый

Прочие свойства

Бренд
REHAB MEDIC

Описание

RehabMedic EMS Digital EV805 The Comfy EMS® has 3 output modes of options including Constant, Synchronous and Alternate. Wide ranges of parameters controlled by press buttons are very convenient for the physical therapist to create a new program. Technical Specifications: - Channel: Dual, isolated between channels - Pulse Amplitude: Adjustable 0-100 mA into 500 ohm load each channel - Output Voltage: Adjustable 0-50V, Max output 50V peak to peak into 500ohm load each channel - Wave Form: Asymmetrical rectangular biphasic pulse - Power Supply: One 9 Volt Battery, type 6F22 - Size: 10.1cm(L) x 6.1cm(W) x 2.45cm(H) - Weight: 150 grams (battery included) - On Time: Adjustable, 2~90 seconds , 1 Sec./ step - Off Time: Adjustable, 0~90 seconds , 1 Sec./ step - Ramp Time: Adjustable, 1~8 seconds, 1 Sec./ step, The “On” time will increase and decrease in the setting value - Pulse Rate: Adjustable, 2~150 Hz , 1Hz / step - Pulse Width: Adjustable, 50~300µs , 10µs / step - Timer: Adjustable, 1-60 minutes or Continuous, Adjustable in 1 minute each step from 1 to 15 minutes, and 5 minutes each step from 15 to 60 minutes. Treament time countdown automatically - Output Mode: Constant ,Synchronous, Alternate - Constant: Constant stimulation based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. “Constant” is equal to the “Normal” mode of a TENS unit - Synchronous: Stimulation of both channels occurs synchronously. The “ON” time including “Ramp Up” and “Ramp Down” time. Therefore, the setting of ON Time should be no less than two times of the “Ramp” time in this mode. ON TIME ≥Ramp up + Ramp down - Alternate: The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the “Ramp” time. The OFF Time should be equal or more than the ON Time ON TIME ≥Ramp up + Ramp down, OFF TIME ≥ON TIME - Compliance Meter: This unit can store 60 sets of operation records. Total recorded time is 999 hours - Low Battery Indicator: A low battery indicator will show up on the LCD when battery is low - Operating Temperature:0°~40℃, Condition Relative Humidty:30%~75%, Atmosphere Pressure : 700Hpa~1060Hpa - Tolerance There may be a +/-5% tolerance of all settings and +/- 20% tolerance of output amplitude and voltage Standard Accessories - 4x4 cm Adhesive Electrodes (4 pieces) - Electrodes Leads (2 pieces) - 9 V Battery, type 6F22 (1 piece) - Instruction Manual (1 piece) - Carrying Case (1 piece)